LCD VU Meter
A dot-matrix bar-graph level meter for the LCD Display, lit in whole segments, with peak and RMS bars, peak hold, a dot mode, a scale, a readout and a clip light.
Installation
$ pnpm dlx shadcn@latest add @audiocn-solid/lcd-vumeterThe CLI also adds the LCD Display and the Level Meter it is built from.
Usage
import {
LcdDisplay,
LcdDisplayLabel,
LcdDisplayRow,
} from "@/components/ui/lcd-display";
import { LcdVuMeter } from "@/components/ui/lcd-vumeter";<LcdDisplay>
<LcdDisplayRow>
<LcdDisplayLabel>Input</LcdDisplayLabel>
<LcdVuMeter source={analyser.meter} />
</LcdDisplayRow>
</LcdDisplay>An LCD VU Meter is a Level Meter drawn as an LCD bar graph. It takes the same source, peakDb, rmsDb, channels, ballistics, zones, taper and actionsRef, and reports the same meter role and values. The level is snapped down to whole segments, so a segment is either lit or not, like the hardware. Put it inside an LcdDisplay: it draws in the display's ink, glows in the dark appearance, and the screen's dot mask breaks the segments into pixels.
Inside an LcdDisplayRow, the meter is named by the row's LcdDisplayLabel. Outside one, give it an aria-label.
For a recorder-style screen with block segments, a printed scale and a CLIP flag, see LCD Meter.
Anatomy
<LcdVuMeter source={analyser.meter}>
<LcdVuMeterChannels>
<LcdVuMeterChannel index={0}>
<LcdVuMeterTrack>
<LcdVuMeterBar measure="rms" />
<LcdVuMeterBar measure="peak" />
<LcdVuMeterHold />
</LcdVuMeterTrack>
</LcdVuMeterChannel>
<LcdVuMeterScale />
</LcdVuMeterChannels>
<LcdVuMeterValue />
<LcdVuMeterClip />
</LcdVuMeter>The parts match the Level Meter's. LcdVuMeterTrack draws the unlit segments, each LcdVuMeterBar lights the segments up to its measure, and LcdVuMeterHold is the peak-hold segment.
With no children, LcdVuMeter renders LcdVuMeterChannels, and LcdVuMeterChannels with no children renders one LcdVuMeterChannel per channel in the data, so a stereo source shows two tracks on its own. An LcdVuMeterChannel with no children renders a track with a peak bar and the hold.
A skin of your own can read the meter's orientation and channel count with useLevelMeterLayout() from the Level Meter's file. Unlike upstream's, it returns accessors, such as channelCount(), as every Solid value here does.
Examples
Values
Pass peakDb (and optionally rmsDb) for data that arrives slowly. The meter still moves smoothly between updates.
Bar and dot
mode="bar" lights every segment up to the level. mode="dot" lights only the top one, like the dot mode of a hardware bar-graph driver. The peak-hold segment shows in both.
Peak and RMS
Layer an rms bar over a translucent peak bar for a dual meter.
Inks
The meter draws in its display's ink, so it follows the display's variant: the theme's --primary by default, or a fixed amber, green, cyan or red. Switch the theme in the sidebar to see the demo above follow it. A custom --lcd-display-ink reaches the meter too.
Vertical
Set orientation="vertical" and give the meter a height. segments sets how many segments the track has; size sets its thickness.
Microphone
Feeding data
The meter is fed exactly like a Level Meter: a frame source, declarative values, or a handle for callers with their own frame loop. See Feeding data.
<LcdVuMeter source={analyser.meter} />
<LcdVuMeter peakDb={-12} rmsDb={-18} />
<LcdVuMeter actionsRef={meterRef} />Theming
The ink comes from the display: --lcd-display-lit for lit segments, mixed into the unlit and dim inks. Outside a display it falls back to currentColor.
| Variable or attribute | Meaning |
|---|---|
--lcd-vumeter-ink | Lit segments, the readout and a lit clip light. Default: var(--lcd-display-lit, currentColor) |
--lcd-vumeter-unlit | Unlit segments and the unlit clip light. Default: the ink at 14% |
--lcd-vumeter-dim | The scale. Default: the ink at 40% |
--lcd-vumeter-gap | The gap between segments. Default: the display's dot pitch |
--lcd-vumeter-segments | The segment count, set from segments |
--lcd-vumeter-lit, --lcd-vumeter-rms, --lcd-vumeter-hold | On each channel: the peak level, the RMS level and the hold, snapped to whole segments (0..1) |
--meter-thickness | The track's thickness, set by size |
--db-readout-tracking | The readout's letter spacing, set to the display's so the meter keeps its width as the digits change |
data-lcd-mode | On the meter: bar or dot |
data-segments | On the meter: the segment count |
data-measure | On each bar: peak or rms |
data-zone, data-clipping, data-active | From the Level Meter, for zone styling |
Segments snap with the CSS round() function, available in every current browser.
Accessibility
The meter is the Level Meter underneath: role="meter" with aria-valuenow in dB and aria-valuetext such as "−12.0 dB", updated at most four times a second. LcdVuMeterClip is the Level Meter's clip indicator: a button that resets it, announcing "Clipping" once per hold. Under reduced motion the meter steps at a calm rate instead of animating.
API reference
LcdVuMeter
Takes every Level Meter prop except variant, plus:
Prop
Type
LcdVuMeterChannel
Prop
Type
LcdVuMeterBar
Prop
Type
LcdVuMeterScale, LcdVuMeterValue, LcdVuMeterClip
They take the props of LevelMeterScale, LevelMeterValue and LevelMeterClip. LcdVuMeterClip is a dot, like the Level Meter's clip light. Its children replace the dot.